As the professional manufacture, we would like to provide you Automatic Doors for Hospital Foot Sensor Switch. And we will offer you the best after-sale service and timely delivery.
Features of Automatic Doors for Hospital Foot Sensor Switch:
With pull in & out socket for easy wiring
Adopt microcomputer control with exquisite design of stainless steel wire cover
Installation with hidden screw hole, easy to be fixed and stable performance
Widely be used in the operating room of hospital and laboratory to prevent hand pollution
Detection mode: Receive the open signal by the truncation of infrared ray which operated by foot
Active infrared ray of modulation-demodulation controlled by microcomputer
Technical measure | Active infrared ray of modulation and demodulation |
Recommend installation height | 0.3m height from the ground |
Detection mode | Truncation of infrared ray by foot operated to produce the open signal |
Reaction time | Relay output <45ms |
Supply power | AC/DC 12~30V |
Stand-by current | 8.2mA |
Operating current | 47mA |
Supervisory signal | 4.5S MA |
Signal output | Relay normally open or normally closed |
Operation temperature | -20℃~55℃ |
Interference immunity | Sunlight 81000LUX, incandescent lamp 36000LUX, electronic microwave conforms to 89336CEE standard |
Hole Size | 130x120x50mm |
Dimension | 186x175x53mm |